This is a refurbished NetApp FAS6030A,IB,ACT-ACT,SupportEdge INC,R5 Filer with a 1-Year overnight parts replacement warranty. The FAS6000 Series is a highly scalable system designed for the largest enterprise level applications and data centers. The FAS6030A,IB,ACT-ACT,SupportEdge INC,R5 is clustered internally to double the performance and fail safe redundancy. The NetApp FAS6030A,IB,ACT-ACT,SupportEdge INC,R5 Filer is expandable to 840 disk drives with a maximum capacity of 420TB. The FAS6000 Series can satisfy multiple needs—SAN, NAS, primary storage, and secondary storage—with a single platform. Supported protocols include FCP, NFS, CIFS, HTTP, and iSCSI.

All used NetApp FAS6030 Filers are rigorously tested on-site in our state-of-the-art hardware engineering lab. The highest quality of refurbishing, technical testing, and certification is guaranteed.

Express Computer systems has the largest inventory of refurbished NetApp hardware on the planet so if you cannot find the used NetApp FAS6030 Filer you need or have a question, please call us at (952) 653-1700 and one of our NetApp specialists will assist you.

Model Number: FAS6030A,IB,ACT-ACT,SupportEdge INC,R5
Max. Raw Capacity: 420TB
Max. Number of Disk Drives: 840
Max. Volume / Aggregate Size: 16TB
ECC Memory: 32GB
Nonvolatile Memory: 1GB

FAS6030A,IB,ACT-ACT,SupportEdge INC,R5 Details:

  • 1 Year Overnight Parts Replacement Warranty Included.
  • Includes rail kits, power cables and all necessary accessories needed for installation.
  • SFPs, FC Cables, SAS Cables, etc available for shelf connections upon request. If filer and shelves are purchased together then all necessary cables are included with purchase at no extra charge.
  • Compatible Disk ShelvesDS4243, DS2246, DS14MK4, DS14MK2-AT, DS14MK2
  • CUSTOM TURN KEY CONFIGURATIONS AND FULL 42U RACKS AVAILABLE. PLEASE INQUIRE FOR DETAILS.


Included Parts List:

  • 2x - FAS6030 Chassis
  • 2x - FAS6030 Motherboard X3949-R5 Controller
  • 8x - X6539-R6 4GB SFP
  • 4x - X6524-R6 2m LC-LC
  • 2x - X877B-R6 Rail Kit II,Cab,R6
  • 4x - X800E-R6-C. Power Cable North America,-C,R6


 Product Highlights
 Operating System  Network Appliance Data ONTAP 7.2.0 software
 Standard Software Features  Integrated automatic RAID manager, including RAID-DP, Snapshot, Fast Boot, telnet, e-mail alerts, NIS, DNS, SNMP, FilerView, FlexVol, FlexShare, NDMP, SSH
 Network Protocol Support  NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS, HTTP 1.0, HTTP 1.1 virtual hosts
 SAN Protocol Support  Fibre Channel Protocol (FCP) for SCSI; fabric-attached and direct-attached; iSCSI
 Licensed Software Products  FlexClone, SnapManager for Microsoft Exchange, SnapManager for Oracle, SnapManager for Microsoft SQL Server, SnapMirror, SyncMirror, SnapVault, SnapRestore, SnapDriveTM, SnapLock, SnapValidator, Clustered Failover, MetroCluster, MultiStore, VFM (Virtual File Manager), DataFabric Manager, ApplianceWatch for HP Openview and Tivoli
 Standard Hardware Features  ROHS-compliant, full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED/LCD, Remote Management Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19" rack-mount enclosure, optional 220 V 42U 19" system cabinet
 Default/Min./Max. RAID Group Sizes  RAID4 (single parity) and RAID-DP (double parity) RAID4 support on FC disks are: Default 7 data + 1 parity/Min. 1 data + 1 parity/Max. 13 data + 1 parity; RAID4 support on SATA disks are: Default and Max. 7 data + 1 parity/Min. 1 data + 1 parity; RAID-DP support on FC disks are: Default 14 data + 2 parity/Min. 1 data + 2 parity/Max. 26 data + 2 parity; RAID-DP support SATA disks are: Default 12 data + 2 parity/Min. 1 data + 2 parity/Max. 14 data + 2 parity
 Disk Shelves Supported
(Fibre Channel, SATA)
 DS14, DS14mk2 FC, DS14mk2AT
 Disk Drive Capacities Supported  FC—9/18/36/72/144/300GB, SATA—250GB, 500GB



 System Specifications  FAS6030
   Active/Active
Configuration
 Single
Controller
 Max. Raw Capacity  420TB  420TB
 Max. Number of Disk Drives  840  840
 Max. Number of FC Loops (dual attach)  10  10
 Max. Drives per FC Loop  84  84
 Max. Volume/Aggregate Size  16TB  16TB
 ECC Memory  32GB  16GB
 Nonvolatile Memory  1GB  512MB
 Onboard GbE Ports  12  6
 Onboard 2Gb Fibre Channel Ports (configurable as Storage-attached initiator or Host-attached target)  16  8
Max. capacity is derived based on the type, size, and number of the drives.
Max. capacity and volume size are calculated using Base10 arithmetic (i.e., 1TB = 1,000,000,000,000 bytes).
Max single controller loops/drives available in Q3CY06.


 I/O Expandability  FAS6030
   Active/Active
Configuration
 Single
Controller
 PCI Express Expansion Slots  10  5
 PCI-X Expansion Slots  6  3
 Optional Network Connectivity (max.)
  Quad GbE TOE (copper) cards
  Single 10GbE TOE (fiber) cards
  Dual GbE (copper or fiber) cards
  Dual iSCSI (copper or fiber) host adapter
 
4
4
10
6
 
2
2
5
3
 Dual FC Disk Adapters (max.)  8  4
 Dual 4GB FC Target Adapters (max.)  8  4
 Dual FC, Single FC, LVD SCSI -Tape Adapters (max.)  6  3



 System Environmental
Specifications
 Active/Active
Configuration
 Single Controller
Configuration
 AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only)  100 to 240VAC, 22 to 10A (typical)
24A (max.) @ 100VAC
200 to 240VAC, 11 to 5A (typical)
12A (max.) @ 200VAC
 100 to 240VAC, 11 to 5A (typical)
12A (max.) @ 100VAC
200 to 240VAC, 5.5A to 2.8A (typical)
6A (max.) @ 200VAC
 Thermal Rating  6142 BTU/hr.  3071 BTU/hr.
 Weight  242 lb (109.6 kg)  121 lb (54.8 kg)
 Height  20.8" (52.8 cm), fits into 12U space  10.3" (26.2 cm), fits into 6U space
 Width  19" IEC rack-compliant (17.53", 44.53 cm)
 Depth  23.5" (59.7 cm), 29.05" (73.8 cm) with cable management bracket
 Operating Temperature, Altitude, and Relative Humidity  10 C to 40 C (50 F to 104 F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, noncondensing (28 C wet bulb temperature)
 Non-operating Temperature and Relative Humidity  -40 C to 65 C (-40 F to 149 F); 10% to 95% relative humidity, noncondensing, in original container
 Operating Acoustic Noise  56.5 dBA sound pressure (LpA) @ normal operating conditions (at 22C and at sea level)
 Min. Cabinet Clearances  1.85" (4.7 cm) for bezel, 3" (7.6 cm) for cable radius
 Min. Service Clearances  25" (63.5 cm) from front of cabinet; 40" (76 cm) from rear of cabinet



 Storage Subsystem Specifications
 Disk Drive Storage Shelf  DiskShelf14 familyDS14, DS14mk2 FC, and DS14mk2AT; each w/14 low-profile slots for FC and SATA disk drives
 Disk Drive Storage Shelf Interface  PCI-based Fibre Channel-Arbitrated Loop (FC-AL)
 DiskShelf14 Interface  Dual, redundant electronically switched hub (ESH2) modules or dual, redundant ATA modules
 Power Supply/Cooling Fans  Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V)
 AC Power/Max. Current  100 to 120VAC/3.95A; 200 to 240VAC/1.9A
 Thermal Rating  1,215 Btu/hr (fully loaded shelf)
 Operating Acoustic Noise  49 dBA sound pressure (LpA) @ normal operating conditions (at 22C and at sea level)
 Dimensions (height/width/depth)  3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
 Weight  77 lb (35 kg) fully loaded



 FAS6000 Series FC Switch SupportTape/SAN
 Vendor  Model
 Brocade  Silkworm 2400/2800 (TapeSAN only)
 Brocade  Silkworm 3200/3250/3800/3850/3900/4100/12000/24000/200E
 McData  ES 3016/3032, Intrepid 6064/6140/ED-5000, Sphereon 3216/3232/4300/4400/4500/4700
 Cisco  MDS 9120/9140/9216/9506/9509/9513



 NetApp Systems Cabinet
 Includes 2 Sets of Dual 16A, Zero U Power Distribution Units (PDUs) or 1 Set of 24A Zero U PDUs  Accommodates 1 filer head and 12 disk shelves or 2 filer heads and 10 disk shelves or 14 disk shelves
1 filer head and 11 disk shelves or 2 filer heads and 8 disk shelves or 14 disk shelves
 AC Power  200 to 240VAC
 Current  32A total2 redundant sets of dual 16A cables with NEMA L6-20 or IEC 309 connectors or Australia AS/NZ53123-20; 24A total 2 redundant cables with NEMA L6-30 or IEC 309 connectors
 Dimensions (height/width/depth)  78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
 Min. Clearances  48" (122 cm) front and rear
 Shipping Height  90.6" (230 cm)
 Weight (empty)  275 lb (125 kg)



 Regulations  NetApp FAS6000 Series Storage System, DiskShelf14
 Safety/Emissions/Immunity  Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI


Associated Model Part Numbers:

  • FAS6030-BAS2-R5-C
  • FAS6030,OS,220V,-C,R5
  • FAS6030-BASE-R5-C
  • FAS6030,OS,-C,R5
  • FAS6030A-IB-BAS-R5
  • FAS6030A,IB,ACT-ACT,HW/SW,R5
  • FAS6030A-IB-BAS2R-R5
  • FAS6030A,IB,ACT-ACT,SupportEdge,INC 220V,R5
  • FAS6030A-IB-BASE-R5
  • FAS6030A,IB,ACT-ACT,SupportEdge INC,R5
  • FAS6030A-IB-BASE2-R5
  • FAS6030A,IB,ACT-ACT,SupportEdge,INC,220V,R5
  • FAS6030A-IB-BASR-R5
  • FAS6030A,IB,ACT-ACT,SupportEdge,INC,R5
  • FAS6030A-IB-BS2-R5 FAS6070A,IB,ACT-ACT,HW/SW,220V,R5
  • FAS6030AS-IB-SYS-R5
  • FAS6030A,ACT-ACT,SAN,SupportEdge INC,R5
  • FAS6030AS-IB-SYS-R5
  • FAS6030A,ACT-ACT,SAN,SupportEdge INC,R5
  • FAS6030AS-SYS-R5
  • FAS6030A,IB,ACT-ACT,CFO,FCP,iSCSI ,OS,R5
  • FAS6030AS-SYS2-R5
  • FAS6030A,IB,A-A,CFO,FCP,iSCSI ,OS,220V,R5
  • FAS6030GX-BNDL-R5
  • FAS6030GX,OS,SFO,NFS,CIFS,FV-HPO,R5
  • FAS6030GX-BNDL2-R5
  • FAS6030GX,OS,SFO,NFS,CIFS,FV-HPO,220V,R5
  • FAS6030A Active-Active Filer Heads
  • FAS6030C Clustered Filer Heads

Buy, sell or lease your Network Appliance FAS6030A,IB,ACT-ACT,SupportEdge INC,R5 Filer with Vibrant Technologies!