This is a refurbished NetApp FAS6080A,HPVALU-BNDL,ACT-ACT,220V,R5 Filer with a 1-Year overnight parts replacement warranty. The FAS6080A,HPVALU-BNDL,ACT-ACT,220V,R5 Filer is a highly scalable system designed for the largest enterprise level applications and data centers. The FAS6080A,HPVALU-BNDL,ACT-ACT,220V,R5 Filer is clustered internally to double the performance and fail safe redundancy. The NetApp FAS6080A,HPVALU-BNDL,ACT-ACT,220V,R5 Filer is expandable to 1,176 disk drives with a maximum capacity of 1,176TB and has 64GB/sec of internal data bandwidth.

All used NetApp FAS6080A,HPVALU-BNDL,ACT-ACT,220V,R5 Filers are rigorously tested on-site in our state-of-the-art hardware engineering lab. The highest quality of refurbishing, technical testing, and certification is guaranteed.

Express Computer systems has the largest inventory of refurbished NetApp hardware on the planet so if you cannot find the used NetApp FAS6080A,HPVALU-BNDL,ACT-ACT,220V,R5 Filer you need or have a question, please call us at (952) 653-1700 and one of our NetApp specialists will assist you.


FAS6080A,HPVALU-BNDL,ACT-ACT,220V,R5 Details:

  • 1 Year Overnight Parts Replacement Warranty Included.
  • Includes rail kits, power cables and all necessary accessories needed for installation.
  • SFPs, FC Cables, SAS Cables, etc available for shelf connections upon request. If filer and shelves are purchased together then all necessary cables are included with purchase at no extra charge.
  • Compatible Disk ShelvesDS4243, DS2246, DS14MK4, DS14MK2-AT, DS14MK2
  • CUSTOM TURN KEY CONFIGURATIONS AND FULL 42U RACKS AVAILABLE. PLEASE INQUIRE FOR DETAILS.


Included Parts List:

  • 2x - FAS6080 Chassis
  • 2x - FAS6080 Motherboard X3942-R5 Controller
  • 8x - X6539-R6 4GB SFP
  • 4x - X6524-R6 2m LC-LC
  • 2x - X877B-R6 Rail Kit II,Cab,R6
  • 4x - X800E-R6-C. Power Cable North America,-C,R6

FAS6000 Series Product Comparison:

 Features  FAS6080  FAS6040
 Application Environments  Large Enterprises and Technical Computing
 Storage Networking Support  FC SAN, IP SAN (iSCSI), FCoE and NAS
 Full Hardware Redundancy  Yes  Yes
 Max. Raw Capacity  1,176TB  840TB
 Max. Disk Drives  1,176  840
 Disk Drive Types  FC and SATA
 Memory  64GB  32GB
 Gigabit Ethernet

Onboard ports

Max. ports
 

12

52
 

12

52
 Fiber Channel

Onboard ports

Max. ports
 

16 x 4GB

56
 

16 x 4GB

56
 PCI Expansion Slots  6PCI-X
10PCI Express
 6PCI-X
10PCI Express

FAS6000 Series Technical Specifications:

 Product Highlights
 Operating System  NetApp Data ONTAP® 7.2.4 or later software
 Operating Systems Supported  Windows® 2000, Windows Server 2003, Windows Server 2008, Windows XP, Linux®, Sun™ Solaris™, AIX, HP-UX, Mac® OS, VMware, ESX
 Standard Software Features  Integrated automatic RAID manager, including RAID-DP™, Snapshot™, Fast Boot, telnet, e-mail alerts, NIS, DNS, SNMP, FilerView®, FlexVol®, FlexShare™, SSH, Maintenance Center, Network Data Management Protocol (NDMP)
 File Service and Other Protocol Support  NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft® CIFS, HTTP 1.0, HTTP 1.1 virtual hosts
 SAN Protocol Support  Fibre Channel Protocol (FCP) (8/4/2/1Gb); fabric-attached and direct-attached; IP SAN (iSCSI), Fibre Channel over Ethernet (FCoE)
 Licensed Software Products  FlexClone™, FlexCache, MultiStore®, SnapMirror®, SnapRestore®, SnapDrive®, SnapManager® for Microsoft Exchange, SnapManager for Microsoft SQL Server, SnapManager for Oracle®, Single Mailbox Recovery, SnapVault®, SnapMover®, SnapLock® Compliance, SnapLock Enterprise, SyncMirror®, MetroCluster, CommandCentral™ Storage, Protection Manager , File Storage Resource Manager, SAN Manager, Operations Manager, ApplianceWatch™ for HP Openview, ApplianceWatch for Tivoli®
 Standard Hardware Features  ROHS-compliant, full-duplex 10/100/1000Base-T Ethernet onboard console, diagnostic LED / LCD, Remote LAN Management (RLM) Card standard, redundant hot-plug cooling fans, redundant hot-plug power supplies, Compact Flash, 19" rack-mount enclosure, optional 220 V 42U 19" system cabinet
 Maximum RAID Group Sizes  RAID 6 (RAID-DP) FC – 28 (26 data disks plus 2 parity disks), SATA – 16 (14 data disks plus 2 parity disks)
RAID 4 FC – 14 (13 data disks plus 1 parity disk), SATA – 7 (6 data disks plus 1 parity disk)
RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)
 Supported Configurations  Highly available controller configurations
Active-active controller with controller failover and multipath HA storage
Active-active controller with stretch (nonswitch) and fabric-attached MetroCluster™
V-Series
Storage Acceleration Appliance SA600
 Disk Shelves Supported (Fibre Channel, SATA) and Configurations  DS14, DS14mk2 FC, DS14mk4 FC, DS14mk2AT
Dual-path
DS4243, MPHA (MultiPath High Availability)
 Disk Drive Capacities Supported  FC-9 / 18/ 36 / 72 / 300GB, 450GB, 600GB
SATA-500GB, 1TB, 2TB
SAS: 300GB, 450GB, 600GB
Protection Manager was previously known as Business Continuance Option.
Operations Manager was previously known as DataFabric® Manager (DFM).
RAID 6 is the recommended configuration for drives greater than 144GB.


 System Specifications  FAS6080  FAS6040
   Active/Active Configuration  Single Controller  Active/Active Configuration  Single Controller
 Max. Raw Capacity  2,352TB  2,352TB  1680TB  1680TB
 Max. Number of Disk Drives  1,176  1,176  840  840
 Max. Number of FC Loops (dual attach)  14  14  10  10
 Max. Drives per FC Loop  84
 Max. Volume/Aggregate Size  16TB
 Max. Number of LUNs per Controller  2048
 ECC Memory  64GB  32GB  32GB  16GB
 Nonvolatile Memory  4GB  2GB  1GB  512MB
 Onboard GbE Ports  12  6  12  6
 Onboard 4Gb FC Ports (target or initiator)  16  8  16  8
Max. capacity is derived based on the type, size, and number of the drives.
Max. capacity is calculated using Base10 arithmetic (i.e., 1TB = 1,000,000,000,000 bytes).
Autosensing ports: 1, 2, 4Gb.


 I/O Expandability  FAS6080  FAS6040
   Active/Active Configuration  Single Controller  Active/Active Configuration  Single Controller
 PCI Express Expansion Slots  10  5  10  5
 PCI-X Expansion Slots  6  3  6  3
 Optional Network Connectivity (max.)
 Quad GbE TOE (copper) Cards
 Quad GbE (copper) Cards
 Single 10GbE TOE (fiber) 10GBASE-SR Cards
 Dual 10GbE TOE (fiber) 10GBASE-SR Cards
 Dual GbE (copper or fiber) Cards
 Dual iSCSI (copper or fiber) Adapters
 

10
10
4

10

10
6
 

5
5
2

5

5
3
 

10
10
4

10

10
6
 

5
5
2

5

5
3
 Dual 4Gb FC Initiator Adapters (max.)  10  5  10  5
 Quad 4Gb FC Initiator Adapters (max.)  10  5  10  5
 Dual 4Gb FC Target (SAN) Adapters (max.)  8  4  8  4
 Dual 10GbE FCoE (copper or fiber) Target (SAN) Adapter (max)  8  4  8  4
 Dual FC, LVD SCSI Tape Adapters (max.)  6  3  6  3
 4port SAS HBA        
 Performance Acceleration Module (PAM)  10  5  8  4
 512GB Flash Cache
(max cards)
 8  4  4  2



 System Environmental
Specifications
 Active/Active
Configuration
 Single Controller
Configuration
 AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240 V only)  100 to 120VAC, 11.2A (typical)
200 to 240VAC, 5.8A (typical)
19.4A (max.) @ 100VAC
9.6A (max.) @ 200VAC
 100 to 120VAC, 5.6A (typical)
200 to 240VAC, 2.9A (typical)
9.7A (max.) @ 100VAC
4.8A (max.) @ 200VAC
 Thermal Rating  3740 Btu/hr, 1096W (typical)  1870 Btu/hr, 548W (typical)
 Weight  242 lb (109.6 kg)  121 lb (54.8 kg)
 Height  20.8" (52.8 cm), fits into 12U space  10.3" (26.2 cm), fits into 6U space
 Width  19" IEC rack-compliant (17.53", 44.53 cm)
 Depth  23.5" (59.7 cm), 29.05" (73.8 cm) with cable management bracket
 Operating Temperature, Altitude, and Relative Humidity  10° C to 40° C (50° F to 104° F); at </= 3,000 m (at </= 10,000') elevation; 20% to 80% relative humidity, noncondensing (28° C wet bulb temperature)
 Nonoperating Temperature and Relative Humidity  -40° C to 65° C (-40° F to 149° F); 10% to 95% relative humidity, noncondensing, in original container
 Operating Acoustic Noise  56.5 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
 Min. Cabinet Clearances  1.85" (4.7 cm) for bezel, 3" (7.6 cm) for cable radius
 Min. Service Clearances  25" (63.5 cm) from front of cabinet; 40" (76 cm) from rear of cabinet



 DS14 Disk Drive Storage Expansion Shelf Specifications
 Disk Drive Storage Shelf  DiskShelf14 family—DS14, DS14mk4 FC, and DS14mk2AT; each w/14 low-profile slots for FC and SATA disk drives
 Disk Drive Storage Shelf Interface  PCI-based Fibre Channel-Arbitrated Loop (FC-AL)
 DiskShelf14 Interface  Dual, redundant electronically switched hub (ESH4) modules or dual, redundant ATA modules
 Power Supply/Cooling Fans  Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V)
 AC Power/Max. Current  100 to 120VAC/4.52A; 200 to 240VAC/2.23A
 Thermal Rating  1,538 Btu/hr (fully loaded shelf)
 Operating Acoustic Noise  49 dBA sound pressure (LpA) @ normal operating conditions (at 22°C and at sea level)
 Dimensions (height/width/depth)  3 EIA U (5.25", 13.3 cm)/19" IEC rack-compliant (17.6", 44.7 cm)/20" (50.85 cm)
 Weight  77 lb (35 kg) fully loaded



 DS4243 Disk Drive Storage Expansion Shelf Specifications
 Disk Drive Types and Capacities Supported  SAS 15,000 RPM: 300GB, 450GB, 600GB
SATA 7,200 RPM: 500GB, 1TB, 2 TB
All shelves have 24 bays for 3.5” low-profile SAS or SATA disk drives
 Disk Enclosure to Controller Interface  Serial Attached SCSI (SAS) operating at 3Gb, requires PCIe SAS Host Bus Adapter card or available embedded SAS port
 Disk Enclosure Configurations  Dual IOM3 (Input/Output Module) Controller modules
 Power Supply/Cooling Fans  Dual (SATA) or quadruple (SAS), redundant, hot-pluggable, integrated power supply/fan assemblies
 Operating Temperature Range  41°F to 104°F - (5°C to 40°C)
 Nonoperating Temperature Range  34°F to 122°F - (1°C to 50°C)
 Relative Humidity  20 to 80% noncondensing
 Operating Acoustic Noise  6.6B LwA @ 20°C
 Input power frequency, Hz (AC)  50 to 60
 Dimensions (height/width/depth)  4 EIA U (7”, 17.8 cm)/19” IEC rack-compliant (19”, 48.3 cm)/24” (61 cm)
 Clearance Dimensions (front-cooling/rear-cooling and maintenance/front-maintenance)  6” (15.3cm)/12” (30.5cm)/25” (55.9cm)
 Weight  110 lb (49.9 kg) fully loaded, 53.7 lbs (24.4 kb) without disk drives
FC = Fibre Channel; LVD = Low Voltage Differential.


 NetApp Systems Cabinet
 Includes 2 Sets of Dual 16A, Zero U Power Distribution Units (PDUs) or 1 Set of 24A Zero U PDUs  Accommodates 1 controller and 12 disk shelves or 2 controllers and 10 disk shelves or 14 disk shelves
1 controller and 10 disk shelves or 2 controllers and 6-8 disk shelves or 11-14 disk shelves only
 AC Power  200 to 240VAC
 Current  32A total-2 redundant sets of dual 16A cables with NEMA L6-20 or IEC 309 connectors or Australia AS/NZ53123-20; 24A total-2 redundant cables with NEMA L6-30 or IEC 309 connectors
 Dimensions (height/width/depth)  78.75" (200 cm)/23.6" (60 cm)/37.4" (95 cm)
 Min. Clearances  48" (122 cm) front and rear
 Shipping Height  90.6" (230 cm)
 Weight (empty)  275 lb (125 kg)



 Regulations  NetApp FAS6000 Series Storage System, DiskShelf14
 Safety/Emissions/Immunity  Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, IRAM, GOST-R, BSMI
Emissions/Immunity: FCC Part 15 Class A, ICES-03, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, EN61000-3-2, EN61000-3-3, CoC (South Africa), BSMI


Associated Model Part Numbers:

  • FAS6080A-CL-BAS-R5
  • FAS6080A,CL,ACT-ACT,HW/SW
  • FAS6080A-CL-BS2-R5
  • FAS6080A,CL,ACT-ACT,HW/SW,220V
  • FAS6080A-HPVALU-BAS2R-R5
  • FAS6080A,HPVALU-BNDL,ACT-ACT,SES,INC,220V,R5
  • FAS6080A-HPVALU-BASE2-R5
  • FAS6080A,HPVALU-BNDL,ACT-ACT,SES INC,220V,R5
  • FAS6080A-HPVALU-BASE-R5
  • FAS6080A,HPVALU-BNDL,ACT-ACT,SES INC,R5
  • FAS6080A-HPVALU-BAS-R5
  • FAS6080A,HPVALU-BNDL,ACT-ACT,R5
  • FAS6080A-HPVALU-BASR-R5
  • FAS6080A,HPVALU-BNDL,ACT-ACT,SES,INC,R5
  • FAS6080A-HPVALU-BS2-R5
  • FAS6080A,HPVALU-BNDL,ACT-ACT,220V,R5
  • FAS6080A-IB-BAS2R-R5
  • FAS6080A,IB,ACT-ACT,SupportEdge,INC,220V,R5
  • FAS6080A-IB-BASE2-R5
  • FAS6080A-IB-BASE-R5
  • FAS6080A,IB,ACT-ACT,SupportEdge INC,R5
  • FAS6080A-IB-BAS-R5
  • FAS6080A,IB,ACT-ACT,HW/SW,R5
  • FAS6080A-IB-BASR-R5
  • FAS6080A,IB,ACT-ACT,SupportEdge,INC,R5
  • FAS6080A-IB-BS2-R5
  • FAS6080A,IB,ACT-ACT,HW/SW,220V,R5
  • FAS6080AS-IB-SYS2-R5
  • FAS6080A,ACT-ACT,SAN,220V,SupportEdge INC,R5
  • FAS6080AS-IB-SYS2R-R5
  • FAS6080A,ACT-ACT,SAN,220V,SupportEdge,INC,R5
  • FAS6080AS-IB-SYS-R5
  • FAS6080A,ACT-ACT,SAN,SupportEdge INC,R5
  • FAS6080AS-IB-SYSR-R5
  • FAS6080AS-SYS2-R5
  • FAS6080A,IB,ACT-ACT,CFO,FCP,iSCSI,OS,220V,R5
  • FAS6080AS-SYS-R5
  • FAS6080A,IB,ACT-ACT,CFO,FCP,iSCSI,OS,R5
  • FAS6080-BAS2-R5-C
  • FAS6080,OS,220V,-C,R5
  • FAS6080-BASE-R5-C
  • FAS6080,OS,-C,R5
  • FAS6080A Active-Active Filer Heads
  • FAS6080C Clustered Filer Heads

Buy, sell or lease your Network Appliance FAS6080A,HPVALU-BNDL,ACT-ACT,220V,R5 Filer with Vibrant Technologies!